EchoNIMBUS SSS

Caution

The Sensor may be connected/disconnected only when the system is powered off.

  • Attach the Universal Heavy Payload mount to the bottom of your drone.
  • Attach the EchoNIMBUS to the Universal Heavy Payload mount.
  • Connect the power cable to the SkyHub power output port #7.
  • Connect the Ethernet cable to the SkyHub Ethernet port #10.

Power on the system.

  • Establish either the drone link or auxiliary connection with the SkyHub in the UgCS-CPM software.
  • On the main screen of the UgCS-CPM, click on the “Payloads” button.
  • From the available payload list, enable the “Cerulean Omniscan 450”.
  • Press the “Save” button and confirm system reload.

Wait until the reload process is finished and the connection to the SkyHub is reestablished.

  • On the main screen of the UgCS-CPM, click the “Start” button.
  • From the drop-down widget list, select the “Cerulean Omniscan 450” and press the blue “plus” button.
  • To access the configuration menu, press on the “three-dot” icon on the upper right corner of the widget and select “Settings”.

EchoNIMBUS SSS Configuration Parameters

ParameterDefaultMinMaxPrecisionUnitOptionsDescription
Min depth0.50.0100.00.1mIf data is lower than this parameter + 1, the value will be red in CPM
Max depth20.00.0100.00.1mIf data is bigger than this parameter - 1, the value will be red in CPM
Measurement interval0.10.0100.00.1sWave emission interval in seconds
Range2001001mMaximal readings range threshold in meters
Gain-1-171dBSet the sensor’s gain. -1 value is for automatic mode.
Speed of sound14810100001mpsSpeed of sound in the target environment, m/s
Deadzone3000100001mmSet the sensor’s deadzone in mm. Start range at which echo data is recorded
Altitude sourceDefaultLightware SF30D, Ainstein US-D1, Nanoradar NRA24, Mavlink (autopilot), DefaultSelect the altimeter as a source of height above surface
Data log dir/data/skyhub_logsPath on SkyHub storage where to put the log files in SVLOG format
IP address left192.168.0.11Left sensor’s IP address to connect
IP address right192.168.0.10Right sensor’s IP address to connect
TCP Port512000655351Sensor’s TCP port to connect
Min sensor depth0.10.0100.00.1mMinimal reading depth threshold in meters
Mounting length0.60.0100.00.01mMounting cable or arm length in meters
Pulse length0.20.0100.00.1%% of total ping time for current range. 0.2 is typical.
Filter duration0.150.0100.00.1%Filter duration. 0.15 is typical.
Signal data points120020012001Number of signal data points in resulting profile
Left transducer angle-90-1801801degreeAngle of sight of the left transducer, degree
Right transducer angle90-1801801degreeAngle of sight of the right transducer, degree
Payload Id1921922201Payload Id