Wind Sensor (FTT)

Caution

The Sensor may be connected/disconnected only when the system is powered off.

  • Attach the pole holding the sensor to the drone using two mounting places.
  • Tighten the first mount (at the bottom of the pole) to the leg of the drone.
  • Tighten the second mount (at the middle of the pole) to the top of the drone.
  • Connect the data cable to SkyHub Connector #4 (white).

Power on the system.

  • Establish either the drone link or auxiliary connection with the SkyHub in the UgCS-CPM software.
  • On the main screen of the UgCS-CPM, click on the “Payloads” button.
  • From the available payload list, enable the “Wind sensor (FTT)”.
  • Press the “Save” button and confirm system reload.

Wait until the reload process is finished and the connection to the SkyHub is reestablished.

  • On the main screen of the UgCS-CPM, click the “Start” button.
  • From the drop-down widget list, select the “Wind sensor (FTT)” and press the blue “plus” button.
  • To access the configuration menu, press on the “three-dot” icon on the upper right corner of the widget and select “Settings”.

Wind Sensor (FTT) Configuration Parameters

ParameterDefaultMinMaxPrecisionUnitOptionsDescription
Min wind speed0.00.0100.00.01mpsMinimal wind speed limit
Max wind speed50.00.050.00.01mpsMaximal wind speed limit
Raw logFalseWrite raw data byte stream into separate log
Serial deviceConnector #4 (AMA3)Connector #2 (S0), Connector #4 (AMA3), Connector #5 (AMA4)SkyHub connector number where altimeter is connected
Baud rate38400bps19200, 38400, 57600Connection port baud rate, 38400 recommended by manufacturer
Payload Id2171922201Payload Id